Understanding Network Connection Methods

See the table below for a representation of how the equipment interfaces connect in a network environment.

Equipment Interface Network Connection Method
  Standalone Terminal Server
Canon USB cable USB cable
CenterVue Wireless router
Wired Ethernet cable
Wireless router
Wired Ethernet cable
Diopsys Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
EyeScape Serial RS-232 cable Contact Synemed to determine if the Eyescape equipment will run on an OS server and if any additional licensing needs to be purchased when using it with a Terminal Server.
Haag-Streit Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Heidelberg/HRT Serial RS-232 cable Contact Heidelberg Engineering to determine if the Heidelberg/HRT equipment will run on an OS server and if any additional licensing needs to be purchased when using it with a Terminal Server.
Humphrey HFA Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Humphrey Matrix 715 Serial RS-232 cable
Connect using COM 1 only
Not supported
Humphrey Matrix 800 Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Huvitz Serial RS-232 cable
Multiple serial ports per PC are supported
Serial RS-232 cable
Multiple serial ports per PC are supported
iMACAM Use the IMACAM cable and follow the IMACAM setup instructions Not supported
Konan Serial RS-232 cable Serial RS-232 cable
Only one camera per Terminal Server
Kowa Serial RS-232 cable Serial RS-232 cable
Only one camera per Terminal Server
MacuLogix Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Marco Serial RS-232 cable
Multiple serial ports per PC are supported
Serial RS-232 cable
Multiple serial ports per PC are supported
NIDEK NAVIS-EX Connected to the computer through a mapped network drive Not supported
OCULUS Connected to the computer through a mapped network drive Not supported
Optos Serial RS-232 cable (Capture and V2 Vantage) Contact Optos to determine if the Optos Capture and Optos Review applications will run on an OS server and if any additional licensing needs to be purchased when using it with a Terminal Server.
Optovue Embedded Windows-computer

Embedded Windows-computer

Only one camera per Terminal Server

Reichert Serial RS-232 cable
Multiple serial ports per PC are supported
Serial RS-232 cable
Multiple serial ports per PC are supported
Topcon CL, KR, & RM Serial RS-232 cable
Multiple serial ports per PC are supported
Serial RS-232 cable
Multiple serial ports per PC are supported
Topcon CT-80 Serial RS-232 cable
Multiple serial ports per PC are supported
Serial RS-232 cable
Multiple serial ports per PC are supported
Topcon CV-5000, CV-5000S, CV-3000, & CV-2500 Serial RS-232 cable
Multiple serial ports per PC are supported
Serial RS-232 cable
Multiple serial ports per PC are supported
Topcon IMAGEnet 6 Web-based browser Contact Topcon to determine if the IMAGEnet 6 software application will run on an OS server and if any additional licensing needs to be purchased when using it with a Terminal Server.
Visionix Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Vmax Vision PSF Refractor Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Woodlyn Serial RS-232 cable Serial RS-232 cable
Only one camera per Terminal Server
Zeiss Cirrus OCT Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Zeiss CLARUS USB cable USB cable
Zeiss i.Com Wireless connection to a UNC path Wireless connection to a UNC path
Zeiss i.Scription & i.Profiler You can use this equipment in a standalone environment, but no connection method is necessary. You can use this equipment in a standalone environment, but no connection method is necessary.
Zeiss FORUM Connected to the computer through a mapped network drive Connected to the computer through a mapped network drive
Zeiss VISUPAC Connected to the computer through a mapped network drive VISUPAC software must be installed on the same computers as ExamWRITER Connected to the computer through a mapped network drive VISUPAC software must be installed on the same computers as ExamWRITER
Zeiss VISULENS, VISUPLAN, & VISUREF Serial RS-232 cable Serial RS-232 cable