Using the Zeiss i.Profiler & i.Scription Interface

  1. Ensure that the Zeiss IP2.MatheTray program is running.

    The IP2.MatheTray.exe is in the \Program Files\CZV folder. The program is running if a Zeiss icon appears in your Windows taskbar.

  2. Open ExamWRITER and open the patient's exam.
  3. In the ExamWRITER chart window, click the Interfaces icon.
  4. Select Zeiss:iProfilerPlus.

    ExamWRITER does the following:

    • Exports patient demographic data to the Zeiss i.Profiler equipment

    • Imports auto refraction data from the Zeiss i.Profiler equipment

    • Displays the data in the Auto Refraction box on the Vision/Rx tab in the ExamWRITER chart window

  5. To export the manifest Rx to the Zeiss i.Scription software, perform the following tasks. Otherwise, go to step 7.
    1. Click the Auto Refraction box on the Vision/Rx tab in the ExamWRITER chart window.
    2. Click Copy to Manifest to copy the auto refraction Rx to the manifest Rx. Otherwise, go to step 7.
    3. To create a prismatic Rx in the Zeiss i.Scription software, ensure that the H Prism and V Prism values are recorded for the patient.
    4. Click Save/Exit.
  6. In the ExamWRITER chart window, click the Interfaces icon.
  7. Select Zeiss:iScription Export.

    The auto refraction Rx and manifest Rx, if recorded, are exported from ExamWRITER and imported into the Zeiss i.Scription software.

  8. Open the i.Scription software from the task bar.

    The i.Scription Software - Review window opens.

  9. At the bottom of the window, click i.Scription.

    The i.Scription Software - iScription window opens.

  10. If you recorded H prism and V prism values in the patient’s manifest Rx in ExamWRITER and you want to create a prismatic Rx for the patient, click Prismatic prescription.
  11. Click Calculate i.Scription.

    The Rx is calculated to the one-hundredth decimal point and displayed in the i.Scription table.

  12. Click one of the following buttons:
    • i.Scription to Final Rx to use the calculated i.Scription Rx as the patient’s final Rx.
    • Manifest to Final Rx to use the calculated i.Scription Rx as the patient’s manifest Rx.
  13. Click Export.

    The final Rx or manifest Rx is exported to ExamWRITER and the Pontus Information window opens.

  14. Click OK.
  15. Close the i.Scription software.
  16. In the ExamWRITER chart window, click the Interfaces icon.
  17. Select Zeiss:iScription Import.

    The Rx exported from the i.Scription software is imported into the Final Spectacle Rx box on the Vision/Rx tab in the ExamWRITER chart window.